MX130 S2 Upgrade and Maintenance Manual 201
System board and components
12.1.2 Preliminary steps
Before replacing the CMOS battery, perform the following steps:
Ê Follow all procedures described in section "Opening the server" on page 48.
12.1.3 Removing the CMOS battery
Figure 125: Removing the CMOS battery
Ê Press out on the locking spring to eject the depleted CMOS battery (1).
Ê If the CMOS battery cannot be ejected this way, use a toothpick
(recommended) or similar tool as a lever: Insert the toothpick between the
battery and locking spring as shown.
V CAUTION!
Do not use sharp-edged tools like screw drivers as they may damage
system board components when slipping.