88 Upgrade and Maintenance Manual MX130 S2
HDDs and accessible drives
7.4 Removing 3.5-inch HDD out of
HDD1 / HDD2 chassis bay
7.4.1 Required tools
Preliminary and concluding steps: tool-less
Removing a 3.5-inch HDD: tool-less
7.4.2 Preliminary steps
Before removing a 3.5-inch HDD, perform the following steps:
Ê Ensure that the HDD to be removed is not combined into a RAID array. If the
drive is part of a RAID array, you first need to delete the array using
ServerView RAID Manager.
V CAUTION!
All data on all HDDs in the array will be lost! Be sure to back up your
data before deleting a RAID array.
I For further information, please refer to the "ServerView Suite RAID
Management" user guide, available online at
http://manuals.ts.fujitsu.com or from the ServerView Suite DVD 2
supplied with your PRIMERGY server.
Ê Follow all procedures described in section "Opening the server" on page 48.
Ê Open the front cage as described in section "Opening the front cage" on
page 52.
Upgrade and Repair Units (URU)
Average task duration: 5 minutes