214 Upgrade and Maintenance Manual
TX140 S2
Main memory
Ê Align the notch on the bottom of the module with the crossbar in the slot (see
close-up).
Ê Press down on the memory module until the securing clips snap into the
cutouts at each end of the module (2).
10.3.3 Concluding steps
Ê "Installing the fan module" on page 152
Ê "Reassembling" on page 58
Ê "Connecting the server to the mains" on page 67
Ê "Switching on the server" on page 68
Ê If applicable, "Updating or recovering the system board BIOS and iRMC" on
page 75
Ê "Enabling SVOM boot watchdog functionality" on page 85
Ê If applicable, "Verifying the memory mode" on page 86
Ê "Enabling BitLocker functionality" on page 90
10.4 Replacing memory modules
10.4.1 Preliminary steps
Ê Identify the defective memory slot using the server management software.
Ê "Disabling BitLocker functionality" on page 69
Ê "Disabling SVOM boot watchdog functionality" on page 70
Ê "Locating the defective server" on page 43
Ê "Shutting down the server" on page 46
Upgrade and Repair Unit
(URU)
Hardware: 5 minutes
Software: 5 minutes
Tools: tool-less

Table of Contents