Page #353 background imageLoading...
Page #353 background image
GEN7iB
353
REAL-TIME FORMULA DATABASE CALCULATORS
REAL-TIME FORMULA DATABASE CALCULATORSA
Real-time Formula Database Calculators (Option to be ordered separately)
Operation Sample based
results syn-
chronous
Cycle based
results asyn-
chronous
Storage in
PNRF recording
Real-time
output
FilterChebyshevHP
FilterChebyshevLP
Special category calculation
HarmonicsIEC61000
Integrate
Signal transformation
DQZeroTransforma-
tion (Park)
(3)
(1)
SpaceVectorTrans-
formation
(3)
SpaceVectorInverse
Transformation
(3)
Signal generation
SineWave
Ramp
Trigger functions
TriggerOnBoolean-
Change
Trigger mark
TriggerOnLevel
Trigger mark
(1) Only cycle based results can be used for real-time output. Use the CycleMean calculation
on recorded channel data or sample based results to enable the real-time output of this
data.
(2) The time required to calculate the output depends on maximum cycle length and sample
rate. Depending on the selected settings the output latency will increase. HBM refers to
these calculations as not deterministic. All real-time output published values (deterministic
and/or not deterministic) will always have the same latency.
(3) This formula is only available if the eDrive license is added to Perception.
(4) The output of HWFilter is used for CycleDetect.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HBK GEN7iB GEN Series and is the answer not in the manual?

HBK GEN7iB GEN Series Specifications

General IconGeneral
BrandHBK
ModelGEN7iB GEN Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals