H ApplicationSpecicUsage
H.1 Calculatingmaximumbercablelength
Maximumopticalberlengthisdeterminedbytwomajorfactors:opticallossand
bandwidthlimit.Thesetypesofopticalberperformanceandqualityaredenedinthe
ISO standard ISO/IEC 11801.
Calculatingbercablelengths
OMx/OCx = ISO/
IEC 11801
standard (optical
bertype)
For
wavelength
Optical
power
budget
Cable loss Coupler
loss.
ANSI/TIA/
EIA-568-A
BW Length
limit
OM1 = Multi Mode
62.5/125 µm
850 nm 8 dB -3.5 dB/km -0.75 dB 200 MHz*km
OM2 = Multi Mode
50/125 µm
850 nm 8 dB -3.5 dB/km -0.75 dB 500 MHz*km
OM3 = Multi Mode
50/125 µm
laser optimized
ber
850 nm 8 dB -3.5 dB/km -0.75 dB 2000 MHz*km
OM4 = Multi Mode
50/125 µm
laser optimized
ber
850 nm 8 dB -3.5 dB/km -0.75 dB 4700 MHz*km
OS1 = Single Mode
9/125 µm
1310 nm 10 dB -1 dB/km -0.75 dB N/A
OS2 = Single Mode
9/125 µm
1310 nm 10 dB -0.4 dB/km -0.75 dB N/A
Notice
Table shows worst-case speciîž’cations.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HBK GEN7iB GEN Series and is the answer not in the manual?

HBK GEN7iB GEN Series Specifications

General IconGeneral
BrandHBK
ModelGEN7iB GEN Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals