321
Jog Frequency – The jog speed setting is used whenever the Jog command is active.
The jog speed setting range is arbitrarily limited to 10 Hz, to provide safety during
manual operation. The acceleration to the jog frequency is instantaneous, but you can
choose from three modes for the best method for stopping the jog operation.
“A” Function
Run
Mode
Edit
Defaults
Func.
Code
Name Description Lnitial data Units
A038
Jog frequency Defines limited speed for jog,
range is from start frequency to
9.99 Hz
Define how end of jog stops the
motor; six options:
00Free-run stop (invalid
during run)
01Controlled deceleration
(invalid during run)
02DC braking to stop(invalid
during run)
03Free-run stop (valid during
run)
04Controlled deceleration
(valid during run)
05DC braking to stop(valid
during run)
6.00 Hz
A039
Jog stop mode
U
04
Note 1: For jogging operation, turn JG terminal ON at first and then turn FW or RV terminal
on.
Note 2: When jogging stop mode A039=02 or 05, DC braking data is needed.
Note 3: During jogging operation, frequency can be set with output frequency setting F001.