Loading...
49
Recommended ferrule
For safe wiring and reliability, it is recommended to use following ferrules.
Wire size
mm
2
(AWG)
Model name of
ferrule *
L [mm] Φd [mm] ΦD [mm]
0.25 (24) AI 0.25-8YE 12.5 0.8 2.0
0.34 (22) AI 0.34-8TQ 12.5 0.8 2.0
0.5 (20) AI 0.5-8WH 14 1.1 2.5
0.75 (18) AI 0.75-8GY 14 1.3 2.8
* Supplier: Phoenix contact
Crimping pliers: CRIPMFOX UD 6-4 or CRIMPFOX ZA 3
How to connect?
(1) Push down an orange actuating lever by a slotted screwdriver (width 2.5mm max.).
(2) Plug in the conductor.
(3) Pull out the screwdriver then the conductor is fixed.
8
L
Φd
ΦD
Push down an
orange actuating
lever.
2.5mm
Plug in the
conductor.
Pull out the
screwdriver to fix
the conductor.