4−50
Permission of Run command
This function allows you to accept run command.
Option
Code
Terminal
Symbol
Function Name State Description
84
ROK Permission of Run
command
ON Run command can be accepted
OFF Run command is ignored
Valid for inputs:
C001~C007
Example (default input configuration
shown—see page 3–84):
See I/O specs on page 4–6.
Required settings
Notes:
Rotation direction detection
Input terminal (7) is for inputting “B pulse”, which is used for detecting the rotation
direction.
Option
Code
Terminal
Symbol
Function Name State Description
85
EB Rotation direction
detection
ON
OFF
Valid for inputs:
C007
Example (default input configuration
shown—see page 3–84):
See I/O specs on page 4–6.
Required settings
Notes:
EB input terminal is dedicated terminal (7).
Maximum allowable input frequency is 2kHz.
Display limitation
This function is to show only the contents of d001 display.
Option
Code
Terminal
Symbol
Function Name State Description
86
DISP Display limitation ON
OFF
Valid for inputs:
C001~C007
Example (default input configuration
shown—see page 3–84):
See I/O specs on page 4–6.
Required settings
Notes:
ROK
7654321L
PCS
P24
DISP
7654321L
PCS
P24
PLC
PLC