48
Sink/source logic of intelligent input terminals
Sink or source logic is switched by a short bar as below.
Wire size for control and relay terminals
Use wires within the specifications listed below. For safe wiring and reliability, it is
recommended to use ferrules, but if solid or stranded wire is used, stripping length should be
8mm.
Solid
mm
2
(AWG)
Stranded
mm
2
(AWG)
Ferrule
mm
2
(AWG)
Control logic
terminal
0.2 to 1.5
(AWG 24 to 16)
0.2 to 1.0
(AWG 24 to 17)
0.25 to 0.75
(AWG 24 to 18)
Relay terminal
0.2 to 1.5
(AWG 24 to 16)
0.2 to 1.0
(AWG 24 to 17)
0.25 to 0.75
(AWG 24 to 18)
Control lo
g
ic terminal
Relay output terminal
8mm