232
4. Set the Motor Current – The inverter has thermal overload protection that is
designed to protect the inverter and motor from overheating due to an excessive load.
The inverter’s uses the motors current rating to calculate the time-based heating effect.
This protection depends on using correct current rating for your motor. The level of
electronic thermal setting, parameter B012, is adjustable from 20% to 100% of the
inverter’s rated current. A proper configuration will also help prevent unnecessary
inverter trip events.
Read the motors current rating on its manufacturers nameplate. Then follow the steps
below to configure the inverter’s overload protection setting.
Action Display Func./Parameter
(Starting point)
A082
AVR voltage select
Press the ESC key.
b001
First “B” Group parameter selected
Press the U key and hold until Æ
b012
Level of electronic thermal setting
Press the SET key.
b160
Default value will be 100% of inverter
rated current
Press the U / V key to select
b140
Set to your motor specs (your display
may be different)
Press the SET key.
b012
Store parameter, returns to “b012