Acceleration stop/Deceleration stop – The acceleration stop and deceleration stop
frequency setting allows you to make the inverter wait, upon starting the motor or upon
decelerating the motor, until the motor slip becomes less when the motor load causes a
large moment of inertia. Use this function if the inverter trips because of overcurrent
when starting or decelerating the motor. This function operates with every acceleration
and deceleration pattern, regardless the acceleration and deceleration curve selection
(A097 and A098). Instead of setting A069,A070,A154 and A155, acceleration and
deceleration can be held by intelligent input configured as "83:HLD".
“A” Function
Run
Mode
Edit
Defaults
Func.
Code
Name Description Lnitial data Units
A069
Acceleration hold frequency Sets the frequency to hold
acceleration, range is 0.0 to
400.0Hz
Sets the duration of
acceleration hold, range is 0.0
to 60.0 seconds
U
0.00 Hz
A070
Acceleration hold time
U
0.0 sec.
a154
Deceleration hold frequency Sets the frequency to hold
deceleration, range is 0.0 to
400.0Hz
U
0.0
Hz
a155
Deceleration hold time Sets the duration of
deceleration hold, range is 0.0
to 60.0 seconds
U
0.0
sec.
A070
A069
A154
A155
HLD input
Output frequency
t
Output frequency
t