C2
Introduction
This appendix lists the user-programmable parameters for the WJ200 series inverters
and the default values for European and U.S. product types. The right-most column of
the tables is blank, so you can record values you have changed from the default. This
involves just a few parameters for most applications. This appendix presents the
parameters in a format oriented toward the keypad on the inverter.
Parameter Settings for Keypad Entry
WJ200 series inverters provide many functions and parameters that can be configured
by the user. We recommend that you record all parameters that have been edited, in
order to help in troubleshooting or recovery from a loss of parameter data.
Main Profile Parameters
NOTE:. Mark “9” in B031=10 shows the accessible parameters when B031 is set “10”,
high level access.
“F” Function
Run
Mode
Edit
Defaults
Func.
Code
Name Description Lnitial data Units
F001
Output frequency setting Standard default target
frequency that determines
constant motor speed, range is
0.0 / start frequency to
maximum frequency (A004)
9
0.0 Hz
F002
Acceleration time (1) Standard default acceleration,
range is 0.01 to 3600 sec.
9
10.0 sec.
F202
Acceleration time (1),
2
nd
motor
9
10.0 sec.
F003
Deceleration time (1) Standard default deceleration,
range is 0.01 to 3600 sec.
9
10.0 sec.
F203
Deceleration time (1),
2
nd
motor
9
10.0 sec.
F004
Keypad RUN key routing Two options; select codes:
00 Forward
01 Reverse
U
00
Inverter model
WJ200
MFG. No.
This information is printed
on the specification label
located on the right side
of the inverter