3−100
Miscellaneous Functions
The following table contains miscellaneous functions not in other function groups.
“C” Function
Run
Mode
Edit
Defaults
Func.
Code
Name Description Lnitial data Units
C091
Debug mode enable * Displays debug parameters.
Two option codes:
00…Disable
01…Enable <Do not set>
(for factory use)
00
−
C101
Up/Down memory mode
selection
Controls speed setpoint for the
inverter after power cycle.
Two option codes:
00…Clear last frequency (return
to default frequency F001)
01…Keep last frequency adjusted
by UP/DWN
U
00
−
C102
Reset selection Determines response to Reset
input [RS].
Four option codes:
00…Cancel trip state at input
signal ON transition, stops
inverter if in Run Mode
01…Cancel trip state at signal
OFF transition, stops inverter
if in Run Mode
02…Cancel trip state at input ON
transition, no effect if in Run
Mode
03…Clear the memories only
related to trip status
U
00
−
C103
Restart mode after reset Determines the restart mode after
reset is given, three option codes:
00…Start with 0 Hz
01…Start with freq. matching
02…Start with active freq.
matching
U
00
−
C104
UP/DWN clear mode Freq. set value when UDC signal
is given to the input terminal, two
option codes:
00…0 Hz
01…Original setting (in the
EEPROM memory at power
on)
U
00
−
CAUTION: Do not change the debug mode for safety reasons. Otherwise unexpected
performances may occur.