3103
“C” Function
Run
Mode
Edit
Defaults
Func.
Code
Name Description Lnitial data Units
C142
Logic output 1 operand A
All the programmable functions
available for logic (discrete) outputs
except LOG1 to LOG3, OPO, no
U
00
C143
Logic output 1 operand B
U
00
C144
Logic output 1 operator Applies a logic function to
calculate [LOG] output state,
Three options:
00[LOG] = A AND B
01[LOG] = A OR B
02[LOG] = A XOR B
U
00
C145
Logic output 2 operand A
All the programmable functions
available for logic (discrete) outputs
except LOG1 to LOG3, OPO, no
U
00
C146
Logic output 2 operand B
U
00
C147
Logic output 2 operator Applies a logic function to
calculate [LOG] output state,
Three options:
00[LOG] = A AND B
01[LOG] = A OR B
02[LOG] = A XOR B
U
00
C148
Logic output 3 operand A
All the programmable functions
available for logic (discrete) outputs
except LOG1 to LOG3, OPO, no
U
00
C149
Logic output 3 operand B
U
01
C150
Logic output 3 operator Applies a logic function to
calculate [LOG] output state,
Three options:
00[LOG] = A AND B
01[LOG] = A OR B
02[LOG] = A XOR B
U
00
Other Functions
To avoid the miss-input of the multi-speed due to the time rug, waiting time to fix the
multi-speed can be set by C169. When input is detected, data is fixed after the time
defined with C169.