358
(2) User setting display mode (b037=02)
The monitor displays only the codes and items that are arbitrarily assigned to user
parameters (U001~U032), except codes d001, F001 and b037.
Refer to User parameter (U001~U032) section for the detail.
(3) Data comparison display mode (
b037=03)
The monitor displays only the parameters that have been changed from the factory
settings. All monitoring indications dxxx and code F001, b190, b191 are always
displayed.
(4) Basic display mode (
b037=04)
The monitor displays basic parameters. (The monitor display is the factory setting.)
The following table lists the parameters that can be displayed in basic display mode.
No. Code displayed Item
1
d001 ~ d104
Monitoring indication
2
F001
Output frequency setting
3
F002
Acceleration time (1)
4
F003
Deceleration time (1)
5
F004
Keypad Rn key routing
6
A001
Frequency source
7
A002
Run command source
8
A003
Base frequency
9
A004
Maximum frequency
10
A005
[AT] selection
11
A020
Multi-speed frequency 0
12
A021
Multi-speed frequency 1
13
A022
Multi-speed frequency 2
14
A023
Multi-speed frequency 3
15
a044
V/F characteristic curve selection
16
a045
V/F gain
17
a085
Energy saving operation mode
18
b001
Restart mode on power failure / under volt. trip
19
b002
Allowable undervoltage power failure time
20
b008
Restart mode on over volt. / over curnt. trip
21
b011
Retry wait time on over volt. / over curnt. trip
22
b037
Function code display restriction
23
b083
Carrier frequency
24
b084
Initialization mode (parameters or trip history)
25
b130
Decel. overvoltage suppression enable
26
b131
Decel. overvoltage suppression level
27
b180
Initialization trigger
28
b190
Password A setting
29
b191
Password A for authentication
30
C021
Output [11] function
31
C022
Output [12] function
32
C036
Alarm relay active state
Initial display selection: b038 The initial display selection function allows you to