Single phase pulse input
Wire phase-A to EA terminal and direction signal to EB terminal. Both sink or source logic
are available for EB terminal by changing position of the short bar. Assign EB in input
terminal 7. ON input is forward and OFF input is reverse direction.
P24
EA
7/EB
PLC
L
Vcc
GND
Out
WJ200
Dir.
Sink type transistor
Encoder
PNP open collector type or
voltage output type encoder
P24
EA
7/EB
PLC
L
Vcc
GND
Out
WJ200
Souce type transistor
Encoder
Dir.
PNP open collector type or
voltage output type encoder
P24
EA
7/EB
PLC
L
Vcc
GND
Out
WJ200
Encoder
PNP open collector type or
voltage output type encoder