361
User Parameter Registration
Parameter group “U” is the user parameter. Any function code can be chosen to registor
on this parameter up to 32. When display mode is set to be “user parameter” (b037= 02)
then is U001 to U032 and d001, F001, b037 are displayed.
“b” Function
Run
Mode
Edit
Defaults
Func.
Code
Name Description Lnitial data Units
b037
Function code display
restriction
Seven option codes:
00Full display
01Function-specific display
02User setting (and b037)
03Data comparison display
04Basic display
05Monitor display only
U
04
u001
~
u032
User parameters 1 to 32 Set range,
no",d001~p183
U
Automatic User Parameter Registration
The automatic user parameter setting function allows you to make the inverter
automatically record changed function codes in U001 to U032. You can use the stored
function codes as a history of data change. To enable this function, select “01” (enabling
automatic user parameter setting) for the b039.
When any data is changed and SET key is pressed, the function code will be stored in
U001 to U032 sequentially.
The latest data is in U001, and the oldest one is in U032.
Stored function codes in U001 to U032 are not duplicated. If duplicated function code is
changed, old existing function code is deleted. If number of changed function code
exceeds 32, the oldest one in U032 is deleted.
“b” Function
Run
Mode
Edit
Defaults
Func.
Code
Name Description Lnitial data Units
B039
Automatic user parameter
registration
Two option codes:
00Disable
01Enable
U
00
u001
~
u032
User parameters 1 to 32 Set range,
no",d001~p183