446
Multistage-position switch (1)~(3)
When “66 (CP1) to68 (CP3)” are assigned to input terminals, you can select position
settings from multistage positions 0 to 7.
Use multistage position settings 0 to 7 (P060 to P067) for the position settings. If no
position settings are assigned to terminals, multistage position 0 (P060) is assumed.
Position setting Parameter CP3 CP2 CP1
Multistage position 0
P060
0 0 0
Multistage position 1
P061
0 0 1
Multistage position 2
P062
0 1 0
Multistage position 3
P063
0 1 1
Multistage position 4
P064
1 0 0
Multistage position 5
P065
1 0 1
Multistage position 6
P066
1 1 0
Multistage position 7
P067
1 1 1
You can specify a delay to be applied at multistage position setting input, until the
relevant terminal input is determined. Use this specification to prevent the application
of fluctuating terminal input before it is determined.
You can adjust the determination time with the multistage speed/position
determination time setting (C169). The input data is finally determined when the
terminal input becomes stable after the delay set as C169. (Note that a long
determination time deteriorates the input terminal response.)
Option
Code
Terminal
Symbol
Function Name State Description
66~68
CP1~CP3 Multistage-position switch
(1)~(3)
ON Multistage position is defined by combination of
the inputs.
OFF
Valid for inputs:
C001~C007
Example (default input configuration
shown—see page 3–84):
See I/O specs on page 4–6.
Required settings
P060~P067
Notes:
Position
command
ON
ON
ON
CP1
CP2
CP3
1
3
7
5
4
Determination time (C169)=0
Determination time
(C169) specified
Determination time (C169)
CP3 CP2
CP1
7654321L
PCS
P24
PLC

Table of Contents

Other manuals for Hitachi WJ200 Series

Related product manuals