EasyManua.ls Logo

Hitachi WJ200 Series

Hitachi WJ200 Series
420 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
B14
Loopback Test [08h]:
This function checks a master-slave transmission using any test data. An example
follows:
Send test data to an inverter having slave address “1” and receiving the test data
from the inverter (as a loopback test).
Query: Response:
No. Field Name
Example
(Hex)
No. Field Name
Example
(Hex)
1 Slave address *1 01 1 Slave address *1 01
2 Function code 08 2 Function code 08
3 Test subcode
(high order)
00 3 Test subcode
(high order)
00
4 Test subcode
(low order)
00 4 Test subcode
(low order)
00
5 Data (high order) Any 5 Data (high order) Any
6 Data (low order) Any 6 Data (low order) Any
7 CRC-16 (high order) CRC 7 CRC-16 (high order) CRC
8 CRC-16 (low order) CRC 8 CRC-16 (low order) CRC
Note 1: Broadcasting is disabled.
When test subcode is for echo (00h, 00h) only and not available to the other commands.

Table of Contents

Other manuals for Hitachi WJ200 Series

Related product manuals