374
Free-V/F Settings Related
Please refer to chapter 3 for detailed explanation of the function.
“b” Function
Run
Mode
Edit
Defaults
Func.
Code
Name Description Lnitial data Units
B100
Free V/F setting, freq.1 Set range, 0 ~ value of b102
U
0. Hz
b101
Free V/F setting, voltage.1 Set range, 0 ~ 800V
U
0.0 V
b102
Free V/F setting, freq.2 Set range, value of b100 ~b104
U
0. Hz
b103
Free V/F setting, voltage.2 Set range, 0 ~ 800V
U
0.0 V
b104
Free V/F setting, freq.3 Set range, value of b102 ~b106
U
0. Hz
b105
Free V/F setting, voltage.3 Set range, 0 ~ 800V
U
0.0 V
b106
Free V/F setting, freq.4 Set range, value of b104 ~b108
U
0. Hz
b107
Free V/F setting, voltage.4 Set range, 0 ~ 800V
U
0.0 V
b108
Free V/F setting, freq.5 Set range, value of b108 ~b110
U
0. Hz
b109
Free V/F setting, voltage.5 Set range, 0 ~ 800V
U
0.0 V
b110
Free V/F setting, freq.6 Set range, value of b108 ~b112
U
0. Hz
b111
Free V/F setting, voltage.6 Set range, 0 ~ 800V
U
0.0 V
b112
Free V/F setting, freq.7 Set range, b110 ~ 400
U
0. Hz
b113
Free V/F setting, voltage.7 Set range, 0 ~ 800V
U
0.0 V