EasyManua.ls Logo

Hitachi WJ200 Series

Hitachi WJ200 Series
420 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
377
When using the brake control function, you are recommended to select the sensorless
vector control (A044=03) that ensures a high torque performance.
“b” Function
Run
Mode
Edit
Defaults
Func.
Code
Name Description Lnitial data Units
B120
Brake control enable Two option codes:
00Disable
01Enable
U
00
b121
Brake Wait Time for
Release
Set range: 0.00 to 5.00 sec
U
0.00 Sec
b122
Brake Wait Time for
Acceleration
Set range: 0.00 to 5.00 sec
U
0.00 Sec
b123
Brake Wait Time for
Stopping
Set range: 0.00 to 5.00 sec
U
0.00 Sec
b124
Brake Wait Time for
Confirmation
Set range: 0.00 to 5.00 sec
U
0.00 Sec
b125
Brake release freq. Set range: 0 to 400Hz
U
0.00 Sec
b126
Brake release current Set range: 0~200% of inverter
rated current
U
(rated
current)
A
b127
Braking freq. setting Set range: 0 to 400Hz
U
0.00 Hz

Table of Contents

Other manuals for Hitachi WJ200 Series