392
Output Function Summary Table
Option
Code
Terminal
Symbol
Function Name Description
OFF Output frequency is higher than the threshold
specified in C063
22
DSE Speed Deviation
Excessive
ON Deviation of speed command and actual speed
exceeds the specified value P027.
OFF Deviation of speed command and actual speed
does not exceed the specified value P027.
23
POK Positioning Completion ON Positioning is completed
OFF Positioning is not completed
24
FA4 Frequency Arrival Type
4–Over frequency
ON When output to motor is at or above the set freq.,
even if in accel (C045) or decel (C046) ramps
OFF When output to motor is OFF, or at a level below the
set frequency
25
FA5 Frequency Arrival Type
5–Set frequency
ON When output to motor is at the set frequency, during
accel (C045) and decel (C046).
OFF When output to motor is OFF, or is not at a level of
the set frequency
26
OL2 Overload Advance
Notice Signal 2
ON When output current is more than the set threshold
(C111) for the overload signal
OFF When output current is less than the set threshold
for the deviation signal
27
ODc Analog Voltage Input
Disconnect Detection
ON
When the [O] input value < B070 setting (signal loss
detected)
OFF When no signal loss is detected
28
OIDc Analog Current input
Disconnect Detection
ON
When the [OI] input value < B071 setting (signal loss
detected)
OFF When no signal loss is detected
31
FBV PID Second Stage
Output
ON Transitions to ON when the inverter is in RUN Mode
and the PID Process Variable (PV) is less than the
Feedback Low Limit (C053)
OFF Transitions to OFF when the PID Process Variable
(PV) exceeds the PID High Limit (C052), and
transitions to OFF when the inverter goes from Run
Mode to Stop Mode
32
NDc Network Disconnect
Detection
ON When the communications watchdog timer (period
specified by C077) has time out
OFF When the communications watchdog timer is
satisfied by regular communications activity
33
LOG1 Logic Output Function 1 ON
When the Boolean operation specified by C143 has
a logical “1” result
OFF
When the Boolean operation specified by C143 has
a logical “0” result
34
LOG2 Logic Output Function 2 ON
When the Boolean operation specified by C146 has
a logical “1” result
OFF
When the Boolean operation specified by C146 has
a logical “0” result
35
LOG3 Logic Output Function 3 ON
When the Boolean operation specified by C149 has
a logical “1” result
OFF
When the Boolean operation specified by C149 has
a logical “0” result
39
WAC Capacitor Life Warning
Signal
ON Lifetime of internal capacitor has expired.
OFF Lifetime of internal capacitor has not expired.
40
WAF Cooling Fan Warning
Signal
ON Lifetime of cooling fan has expired.