2. Remove one grounding screw (callout 3), and disconnect two cables (callout 4).
Figure 5-169 Remove the ADF assembly (2 of 3)
NOTE When you reinstall the ADF, make sure that the ADF cable is correctly routed
through the cable holder into the scanner bed.
3. Open the ADF assembly, and lift it up and off of the scanner.
Figure 5-170 Remove the ADF assembly (3 of 3)
CAUTION The ADF assembly is calibrated to work with the scanner on which it is
installed. If the ADF is installed on another scanner, that scanner needs to be calibrated
to work correctly with the ADF.
320 Chapter 5 Removal and replacement ENWW