Stapler/stacker components
CAUTION Disconnect the MFP power cord from the electrical outlet before disassembling
and reassembling the stapler/stacker. After the device is plugged back in for testing purposes,
do not touch the low-voltage power supply unit because this can cause electrical shock.
Delivery tray
Lift the delivery tray (callout 1) upward (callout 2), then pull it outward (callout 3) and remove.
1
2
3
Figure 5-200 Remove the delivery tray
Front cover
1. Remove the delivery tray.
2. Carefully pry off the front cover using a flat-blade screwdriver. Insert the screwdriver blade and
slightly lift the cover at the five points (callout 1) shown in the following figure.
1
1
Figure 5-201 Claw locations on front cover
Rear cover
1. Remove the delivery tray.
340 Chapter 5 Removal and replacement ENWW