99
Local mode: client, local poll interval: 6
Peer mode: server, peer poll interval: 6
Offset: 0.2862ms, roundtrip delay: 3.2653ms, dispersion: 4.5166ms
Root roundtrip delay: 0.0000ms, root dispersion: 10.910ms
Reachabilities:31, sync distance: 0.0194
Precision: 2^18, version: 3, source interface: Not specified
Reftime: d17cbba5.1473de1e Tue, May 17 2011 9:17:25.079
Orgtime: 00000000.00000000 Thu, Feb 7 2036 6:28:16.000
Rcvtime: d17cbbc0.b1959a30 Tue, May 17 2011 9:17:52.693
Xmttime: d17cbbc0.b1959a30 Tue, May 17 2011 9:17:52.693
Roundtrip delay samples: 0.007 0.010 0.006 0.011 0.010 0.005 0.007 0.003
Offset samples: 5629.55 3913.76 5247.27 6526.92 31.99 148.72 38.27 0.29
Filter order: 7 5 2 6 0 4 1 3
Total sessions: 1
Table 16 Command output
Field Description
Clock source
IP address of the NTP server. If this field displays
0.0.0.0
, the IP
address of the NTP server has not been resolved successfully.
Clock stratum
Stratum level of the NTP server, which determines the clock
accuracy. The value is in the range of 1 to 16. A lower stratum
level represents greater clock accuracy. A stratum 16 clock is not
synchronized and cannot be used as a reference clock.
Clock status
Status of the clock source corresponding to this association:
• configured—The association wascreatedbya configuration
command.
• dynamic—Theassociation is established dynamically.
• master—The clock source is the primary time server of the
current system.
• selected—The clock source has survived the clock selection
algorithm.
• candidate—The clock source is the candidate reference
source.
• sane—The clock source has passed authentication and will
be used as the reference source.
• insane—The clock source has not passed authentication, or
has passed authentication but will not be used as the
reference source.
• valid—The clock source is valid, which means the clock
source meets the following requirements:
{ It has been authenticated and synchronized.
{ Its stratum level is valid.
{ Its root delay and root dispersion values are within their
ranges.
• invalid—The clock source is invalid.
• unsynced—The clock source has not been synchronized or
the value of the stratum level is invalid.

Table of Contents