huawei(config)#interface gpon 0/4
huawei(config-if-gpon-0/4)#ont add 1 ontid 2 sn-auth 32303131B39FD642
omci ont-lineprofile-id 10 ont-srvprofile-id 11
2. (Optional) Bind an alarm profile.
By default, an ONU will be automatically bound to alarm profile 1 (default profile). You
need to manually bind an alarm profile to an ONU only when the default alarm profile does
not meet requirements.
In this example, the default alarm profile is used. Therefore, you do not need to manually
bind an alarm profile.
Step 3 Confirm the ONU status.
After adding an ONU, run the display ont info command to query the current status of the ONU.
Ensure that Control flag is active, Run State is online, and Config state is normal.
The following uses ONU 1 as an example to describe how to confirm ONU status.
huawei(config-if-gpon-0/3)#display ont info 1 1
---------------------------------------------------------------------
F/S/P : 0/3/1
ONT-ID : 1
Control flag : active //Indicates that the ONU is
activated.
Run state : online //Indicates that the ONU is
online.
Config state : normal //Indicates that the ONU is in normal
state.
...//Other command output is omitted.
huawei(config-if-gpon-0/3)#quit
----End
Follow-up Procedure
When Config state is failed, Run state is offline, or Match state is mismatch:
l If Control flag is deactive, run the ont active command in GPON mode to activate the
ONU.
l If Run state is offline, a physical line may be broken or the optical module may be damaged.
Check the line and the optical module.
l If Config state is failed, the configured ONU capability exceeds the actual ONU capability.
In this case, run the display ont failed-configuration command in the diagnose mode to
check the failed configuration item and the failure cause. Then, rectify the fault accordingly.
l If the ONU does not match, that is, Match state is mismatch, the port types and number
of ports undermatch the actual port types and number of ports supported by the ONU. In
this case, run the display ont capability command to query the actual capability of the
ONU, and then select one of the following modes to modify the ONU configuration:
Create a proper ONU profile according to the actual capability of the ONU, and then
run the ont modify command to modify the configuration data of the ONU.
Modify the ONU profile according to the actual capability of the ONU and save the
modification. Then, the ONU automatically recovers the configuration successfully.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
12 FTTO Configuration(SOHO and SME)
Issue 01 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1240

Table of Contents

Other manuals for Huawei SmartAX MA5608T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SmartAX MA5608T and is the answer not in the manual?

Huawei SmartAX MA5608T Specifications

General IconGeneral
Dual Power SupplyYes
Humidity5% to 95% (non-condensing)
Uplink Slots2
Maximum GPON Ports16
Input Voltage Range-38.4 V DC to -72 V DC
Device TypeOLT
Power Supply-48 V DC
Operating Temperature-25°C to +55°C
Storage Temperature-40°C to 70°C
Switching Capacity128 Gbps
PortsGPON, XG-PON, 10GE