Run the display ont-mgc-profile command to query the existing MGC interface profile in
the system. If the existing MGC interface profile in the system does not meet the
requirements, run the ont-mgc-profile add command to add an MGC interface profile.
Create MGC interface profile 2, set the IP address of the MGC to 200.200.200.200, and
use default values for other parameters.
huawei(config)#ont-mgc-profile add profile-id 2 primary-mgc 200.200.200.200
3. Configure a POTS port profile.
Run the display ont-pots-profile command to query the existing POTS port profile in the
system. If the existing POTS port profile in the system does not meet the requirements, run
the ont-pots-profile add command to add a POTS port profile.
In this example, the default POTS port profile, namely POTS port profile 1 is used.
Step 10 Configure the IP addresses of ONT H.248 users.
For ONT 1 and ONT 2, configure the IP address obtaining mode to the dhcp mode, set the
management VLAN to VLAN 20, and use default values for other parameters.
huawei(config)#interface gpon 0/1
huawei(config-if-gpon-0/1)#ont ipconfig 0 1 dhcp vlan 20
huawei(config-if-gpon-0/1)#ont ipconfig 0 2 dhcp vlan 20
Step 11 Configure H.248 PSTN users.
1. Add an H.248 interface and apply an MGC interface profile to the interface.
For ONT 1 and ONT 2, set the MG ID to 1, apply MGC interface profile 2 to ONT 1 and
ONT 2, and use default values for other parameters.
If parameters of an MGC interface profile are changed, the MGC interface profile must be
reapplied to the ONT so that the changed parameters can take effect.
huawei(config-if-gpon-0/1)#if-h248 add 0 1 1 mgc-profile profile-id 2
huawei(config-if-gpon-0/1)#if-h248 add 0 2 1 mgc-profile profile-id 2
2. Add PSTN users.
For ONT 1 and ONT 2, create a PSTN user, set the MG ID to 1 (identical to the MG ID of
the H.248 interface), and set the physical terminal port ID to A0 and A1.
huawei(config-if-gpon-0/1)#mgpstnuser add 0 1 1 mgid 1 terminalid A0
huawei(config-if-gpon-0/1)#mgpstnuser add 0 2 1 mgid 1 terminalid A1
Run the display mgpstnuser attribute command to check whether the configuration of
the PSTN user is properly set.
huawei(config-if-gpon-0/1)#display mgpstnuser attribute 0 1 1
------------------------------------------------------------------------------
F/S/P : 0/1/0
ONT ID : 1
Port ID : 1
MG ID : 1
Terminal ID : A0
...//The rest of the response information is omitted.
huawei(config-if-gpon-0/1)#display mgpstnuser attribute 0 2 1
------------------------------------------------------------------------------
F/S/P : 0/1/0
ONT ID : 2
Port ID : 1
MG ID : 1
SmartAX MA5600T/MA5603T/MA5608T Multi-service