Figure 1-82 shows the flowchart for commissioning the management channel between the OLT
and the GPON ONT.
Figure 1-82 Flowchart for commissioning the management channel between the OLT and the
GPON ONT
Procedure
Step 1 Add a DBA profile.
The DBA profile ID is 12, the DBA profile uses the default name DBA-profile_12, the bandwidth
type is type1 (fixed bandwidth), and the user rate is the fixed 10 Mbit/s bandwidth.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
1 Commissioning
Issue 01 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
180