Item Data
IUA link set parameter IUA link set ID 1
Working mode of a
link set
override
Pending time 10s
Mode of
generating the
interface ID
2
Whether the link in
the link set
supports the
interlocking
enable
Service
environment
corresponding to
the IUA link set
client
IUA link parameter IUA link ID 15
Local port ID 1401
Local IP address 10.13.4.116/16 (It must exist in the signaling
IP address pool.)
Remote port ID 1400
IP address of the
primary MGC
10.14.1.2/16 (IP address of the primary MGC)
MGC that is bound
to the IUA link
primary-mgc
Priority of the IUA
link.
3
IP address of the
primary MGC
10.14.1.2/16 (IP address of the primary MGC)
ISDN PRA port Subrack ID/Slot
ID/Port ID
0/2/0
IUA interface ID 1
TID 512
Procedure
Step 1 Add the EDTB board.
According to the data plan, add an ISDN PRA service board to slot 0/2.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
3 Configuring the DSLAM Services
Issue 01 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
342