EasyManuals Logo

Huawei SmartAX MA5608T User Manual

Huawei SmartAX MA5608T
1979 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #632 background imageLoading...
Page #632 background image
NOTE
l The parameters of the SIP-based voice user must be consistent with the
corresponding configuration on the softswitch.
l If Associated POTS Port is 1, port TEL1 on the ONT is bound. If Associated POTS
Port is 2, port TEL2 on the ONT is bound.
d. Click Apply.
4. Check the registration status of the voice user.
Choose Status > VoIP Information. In the right pane, User Status is Up.
l Configure the ONT on the U2000.
NOTE
l The following configuration procedure is for scenarios with the bridging ONT. For scenarios with the
bridging ONT+HGW, configure the voice service on the HGW but not on the ONT. For detailed
configurations, see the HGW Configuration Guide.
l The window for configuring ONT value-added service (VAS) profiles varies with ONT versions, but
the parameter configuration is the same. For details, see relevant ONT manuals.
1. Configure a general VAS profile for the ONT.
a. From the main menu, choose Configuration > Access Profile Management. In
the navigation tree of the tab page that is displayed, choose PON Profile > ONT
VAS Profile.
b. On the General ONT VAS Profile tab page, right-click, and choose Add from
the shortcut menu.
c. In the dialog box that is displayed, set Name to ONT-VoIP.
d. Configure the parameters of a voice WAN port.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
9 FTTH Configuration
Issue 01 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
607

Table of Contents

Other manuals for Huawei SmartAX MA5608T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SmartAX MA5608T and is the answer not in the manual?

Huawei SmartAX MA5608T Specifications

General IconGeneral
Dual Power SupplyYes
Humidity5% to 95% (non-condensing)
Uplink Slots2
Maximum GPON Ports16
Input Voltage Range-38.4 V DC to -72 V DC
Device TypeOLT
Power Supply-48 V DC
Operating Temperature-25°C to +55°C
Storage Temperature-40°C to 70°C
Switching Capacity128 Gbps
PortsGPON, XG-PON, 10GE