4. Operation
4.2 Operation in Positioner Mode
4-32 ME0342-4B
[Example of rotary actuator of multi-rotation specification in index mode]
Caution
Since this signal becomes effective after the coordinate system is established after the
home return is completed, it would not be output just with the power turned ON.
The zone detection range would not turn ON unless the value exceeds that of the
minimum resolution (actuator lead length/number of encoder pulse).
The number of encoder pulse differs for each actuator series.
RCP2, RCP3, RCP4, RCP5: 800 pulses
RCP6: 8192 pulses
315°
70°
0°
315°
70°
0°
Set Value
Zone setting + : 70°
Zone setting - : 315°
Set Value
Zone setting + : 315°
Zone setting - : 70°