4. Operation
4.2 Operation in Positioner Mode
4-30
ME0342-4B
[5] Zone Signal and Position Zone Signal (ZONE1, ZONE2, PZONE)
PIO signal
Output
ZONE1
ZONE2
(Note 2)
PZONE
(Note 2)
Pattern 0
Pattern 1
(Note 2)
×
Pattern 2
(Note 2)
×
Pattern 3
(Note 1)
×
×
×
Pattern 4
Pattern 5
Pattern 6
Pattern 7
: Available, ×: Unavailable
Note 1 Pattern 3 does not have the zone signal output feature.
Note 2 In Parameter No.149 Zone Output Switchover, ZONE can be selected instead
of PZONE.
The relevant signal can be turned ON while the actuator passes or stops in the zone range in
either of the following 2 types:
1) Zone signal (ZONE1, ZONE2) : The output signal is turned ON at the position set by the
proper parameter.
2) Position zone signal (PZONE) : The output signal is turned ON at the position set in the
position table.
The feature can play a role as the sensor for judging whether the completion position is good or
not in pressing operation, setting the continuous operation zone in pitch feed or interlocking
operations of other units in the setting zone.
Zone signal output
setting zone
OFF
1)
Velocity
Position 1 input
Start signal input
(moving start)
Stop status
ON
Zone output signal
Acceleration
Deceleration
at entry into setup
zone
Position 1 input
Start signal input
(moving start)
Moving
comp.
Positioning
completion
signal output
2)
3)
4)
Time
5)
1)
2)
3)
4)
5)
4.2 Operation in Positioner Mode
ME0342-4B 4-31
(1) Zone signa (ZONE1, ZONE2)
Set the zone range to the relevant parameter.
1) Parameter No.1 : Zone boundary 1+
2) Parameter No.2 : Zone boundary 1
3) Parameter No.23 : Zone boundary 2+
4) Parameter No.24 : Zone boundary 2
The zone signal ZONE is kept effective also during the emergency stop unless the memory of
the origin is lost due to alarm.
(2) Position zone signal (PZONE)
Zone ranges should be set in the position table.
While the operation corresponding to a position number is executed, the zone range set for the
position number is valid. It is kept effective also during the emergency stop unless the actuator
is operated or the memory of the origin is lost due to alarm.
(3) Setting values and signal output range
The zone output range varies depending on the difference between the value set for the positive
side of the zone and that for the negative side.
1) Value set for positive side > value set for negative side: The output signal is set to ON in the
range and OFF out of the range.
2) Value set for positive side < value set for negative side: The output signal is set to OFF in the
range and ON out of the range.
[Example of Line Axis]
Setting of zone range
Current
Position
Zone Signal Output
Zone Signal Output
0mm
30mm
70mm
100mm
ON
ON
ON
Set Value
Zone setting + : 70mm
Zone setting - : 30mm
Set Value
Zone setting + : 30mm
Zone setting - : 70mm

Table of Contents

Other manuals for IAI PCON-CB series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IAI PCON-CB series and is the answer not in the manual?

IAI PCON-CB series Specifications

General IconGeneral
BrandIAI
ModelPCON-CB series
CategoryController
LanguageEnglish

Related product manuals