3. Wiring
3.1 Positioner Mode (PIO Control)
3-3 ME0342-4B
Pin
No.
Category
PIO Functions
Parameter No.25 “PIO Pattern” Selection
Force Sensor Used
Pressing Mode 1
Force Sensor Used
Pressing Mode 2
Input
Number of positioning
points
7 points 3 points 32 points 5 points
(Current position
× × × ×
Output
×
×
×
×
Pulse
Input
Output
(Note 1)
16B OUT15
*ALML *ALML *ALML
(Note) “*” in codes above shows the signal of the active low.
PM1 to PM8 indicate the alarm binary code output signal when an alarm is generated.
Refer to [4.2.4 [7] Binary Output of Alarm Data Output]
(Note 1) The mode can be switched over to PZONE with the setting of Parameter No.149 except for PIO Pattern 3.
(Note 2) PIO Patterns 6 and 7 should be available only when PCON-CBP/CGBP are ordered at purchasing.
(Note 3) It is invalid before home-return operation.