146
In the following example, the BIOS sends a value of ACh to the diagnostic LED decoder. The LEDs are
decoded as follows:
Note: Diagnostic LEDs are best read and decoded when viewing the LEDs from the back of the system.
Table 5. POST Progress Code LED Example
LEDs
Upper Nibble AMBER LEDs
Lower Nibble GREEN LEDs
MSB
LSB
LED #7
LED #6
LED #5
LED #4
LED #3
LED #2
LED #1
LED #0
8h
4h
2h
1h
8h
4h
2h
1h
Status
ON
OFF
ON
OFF
ON
ON
OFF
OFF
Results
1
0
1
0
1
1
0
0
Ah
Ch
Upper nibble bits = 1010b = Ah; Lower nibble bits = 1100b = Ch; the two are concatenated as ACh
Early POST Memory Initialization MRC Diagnostic Codes
Memory Initialization at the beginning of POST includes multiple functions, such as: discovery, channel
training, validation that the DIMM population is acceptable and functional, initialization of the IMC and other
hardware settings, and initialization of applicable RAS configurations.
The MRC Progress Codes are displays to the diagnostic LEDs that show the execution point in the MRC
operational path at each step.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel P4304XXMFEN2 and is the answer not in the manual?

Intel P4304XXMFEN2 Specifications

General IconGeneral
BrandIntel
ModelP4304XXMFEN2
CategoryChassis
LanguageEnglish

Related product manuals