EasyManuals Logo
Home>Intel>Chassis>P4304XXMFEN2

Intel P4304XXMFEN2 User Manual

Intel P4304XXMFEN2
194 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #192 background imageLoading...
Page #192 background image
Intel
®
Server Chassis P4304XXMFEN2/P4304XXMUXX Product Family System Integration and Service Guide
174
Table 15. Integrated BMC Beep Codes
Code
Associated Sensors
Reason for Beep
1-5-2-1
No CPUs installed or first CPU socket is
empty.
CPU1 socket is empty or sockets are populated
incorrectly.
CPU1 must be populated before CPU2.
1-5-2-4
MSID Mismatch
MSID mismatch occurs if a processor is installed
into a system board that has incompatible power
capabilities.
1-5-4-2
Power fault
DC power unexpectedly lost (power good
dropout) power unit sensors report power unit
failure offset.
1-5-4-4
Power control fault (power good
assertion timeout).
Power good assertion timeout – power unit
sensors report soft power control failure offset.
1-5-1-2
VR Watchdog Timer sensor assertion
VR controller DC power on sequence was not
completed in time...
1-5-1-4
Power Supply Status
The system does not power on or unexpectedly
powers off and a Power Supply Unit (PSU) is
present that is incompatible with one or more
other PSUs in the system.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel P4304XXMFEN2 and is the answer not in the manual?

Intel P4304XXMFEN2 Specifications

General IconGeneral
BrandIntel
ModelP4304XXMFEN2
CategoryChassis
LanguageEnglish

Related product manuals