138 
3.  Changing the interval between the parallel line cursors ·························································179 
4.  Using the cross hair cursor ·······································································································179 
3.3.14  Floating VRM and EBL ·········································································································180 
Setting the #1EBL and #1VRM to enable moving ········································································180 
Setting the point of reference and center position·········································································180 
Operating the EBL and VRM··········································································································180 
Canceling the point of reference or center position·······································································180 
3.3.15  Using the parallel line cursor·································································································181 
The parallel line cursor function is set to #1EBL and #1VRM ······················································181 
Operating the parallel line cursor ···································································································181 
Canceling the parallel line cursor ···································································································181 
3.3.16  Switching the EBL and cursor bearing display among relative, true   
and magnetic bearing display mode ·····················································································181 
Selection of bearing criteria (magnetic bearing, gyrocompass bearing)······································183 
Selection of the bearing criteria ······································································································183 
3.3.17  Changing the bearing display method of the PPI screen ···················································183 
Course setting in course-up mode ·································································································185 
3.3.18  Simultaneously measuring the bearing, distance and travel time to the target·················185 
Displaying cursor·····························································································································186 
Moving the cursor····························································································································186 
Erasing the cursor ···························································································································186 
3.3.19  L/L display of the cursor ········································································································187 
3.3.20  Magnifying the echo images on the PPI screen··································································187 
1.  Using the image expansion function ························································································187 
2.  Changing the transmission pulse width ···················································································188 
3.  Using the zoom function ···········································································································189 
Setting the zoom area···············································································································189 
Canceling the zoom ··················································································································190 
3.3.21  Reducing unnecessary noise and emphasizing the target·················································190 
Set the image processing ···············································································································190 
Canceling image processing ··········································································································191 
3.3.22  Moving the center of the PPI screen ····················································································191 
Setting the position to which the center is relocated.····································································191 
Canceling center relocation ············································································································192 
3.3.23  Controlling power consumption of the radar········································································192 
Setting the transmission time ·········································································································192 
Setting the standby time ·················································································································192 
Commencing timed transmission···································································································192 
Canceling timed transmission ········································································································193 
Canceling timed transmission while in standby mode ··································································193