257
(d) Push the soft key 1 and select
EXP
EXPEXP
EXP
OFF
OFFOFF
OFF
.
(e) Push the the soft key
PROCESS
PROCESSPROCESS
PROCESS
.
(f) Push the soft key 1 and select
AUTO
AUTOAUTO
AUTO
OFF
OFFOFF
OFF
.
(g) Turn the [GAIN] control to the maximum (turn to maximum clockwise).
(h) Turn the [SEA] control to the mid position.
(i) Turn the [RAIN] control to the minimum (turn to maximum counterclockwise).
(j) Select "MBS LEVEL" in the menu "INITIAL SETTING 1".
(k)
Adjust the suppression level pushing the "▲ (up)" or "▼ (down)" on the
RANGE
RANGERANGE
RANGE
key.
(l) Push the
ENTER
ENTERENTER
ENTER
key.
The suppression level of the main bang has been determined.
(
m
) Select "MBS RANGE" in the menu "INITIAL SETTING 1".
(n)
Adjust the suppression range pushing the "▲ (up)" or "▼ (down)" on the
RANGE
RANGERANGE
RANGE
key.
(o) Push the
ENTER
ENTERENTER
ENTER
key.
Adjustment of the suppression range of the main bang has been completed.
9.8.9 Display of simulator image
By activating this function, it is possible to display a demonstration screen on the PPI
screen.
To make the setting of this function effective, the power must be once switched off.
(a) Push the
STBY/OFF
STBY/OFFSTBY/OFF
STBY/OFF
key.
The display will enter the standby mode.