Kinco FD5P AC series servo
Chapter 10 Communication
142
SDOSend/Server
1011
581H-
5FFH
1200H
SDO
Receive/Client
1100
601H-
67FH
1200H
NMT Error Control
1110
701H-
77FH
1016H-1017H
Note 1The smaller the COB-ID, the higher the priority;
2The function code in front of each level of COB-ID is in a fixed format
3 COB-IDs are 00H, 80H, 100H, 701H-77FH, and 081H-0FFH, which are all system management
formats.
COB-IDs supported by FD5P series servo drives
Send
PDO
TXPDO
TXBDO refers to the data sent by the servo relative to the servo, and these data are
received by the PLC. The function code (COB-ID) for sending PDO is:
1
0x180+
Servo station NO.
2
0x280+
Servo station NO.
3
0x380+
Servo station NO.
4
0x480+
Servo station NO.
Receive PDORXPDO
Compared with the servo, the receiving PADO refers to the data received by the servo. These data are
sent by the PLC. The function code (COB-ID) of the sending PDO is:
1
0x200+
Servo station NO.
2
0x300+
Servo station NO.
3
0x400+
Servo station NO.
4
0x500+
Servo station NO.
PDO Transmission type
PDO
has two different transmission type
Synchronize
SYNC
)——Transmission triggered by synchronization messages(Transmission type
0-240
In this transmission mode, the controller must have the ability to send synchronization
messages (messages sent periodically with a frequency of up to 1KHZ), and the servo will
send the synchronization message after receiving the message
.
Period - The transfer type is 1-240. Delivery is triggered after every 1 to 240 SYNC
messages. In this mode, the data in the PDO is sent once every time the servo drive
receives n synchronization messages.
Asynchronous (Transmission Type: 254/255)
The message is sent after the slave message data has changed, regardless of whether the
master asks it or not. And can define the time interval between two transmissions of the same
message to avoid high priority messages occupying the bus all the time (the lower the PDO
value, the higher the priority).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kinco FD5P Series and is the answer not in the manual?

Kinco FD5P Series Specifications

General IconGeneral
BrandKinco
ModelFD5P Series
CategoryController
LanguageEnglish

Related product manuals