DETAILED CONTROLS AND GAUGES OPERATION
3-86
Engine Emergency Stop Cancel Switch
Engine emergency stop cancel switch is provided to make it possible to perform work for a short time
when there is a failure in the emergency stop switch system. It is necessary to repair the abnormal loca-
tion as soon as possible.
This switch (22) makes it possible to carry out operations for a
short time when there is an abnormality in the emergency stop
switch system but no monitor lights up and the engine cannot
be started.
(a) When abnormal: Move switch up
(b) When normal: Move switch down
q If there is a failure, such as an abnormality in the emer-
gency stop switch or disconnection in the wiring, and the
engine cannot be started, move this switch (22) up. This
will make it possible to carry out operations.