q If the key in the starting switch is turned to the ON position
when engine emergency stop switch (S) is at ON (emer-
gency stop) position (a), engine emergency stop warning
lamp (C) on the console panel to the left of the operator's
seat inside the cab lights up.
When starting the engine again after stopping it, do as follows.
1. Turn the head of engine emergency stop switch (S) to the
right. The switch will spring out slightly and will be reset to
OFF (normal operation) position (b). When doing this,
check set indicator lamp (L) is off.
2. Turn the starting switch key to the ON position.
3. Check that engine emergency stop warning lamp (C) on
the console panel to the left of the operator's seat inside
the cab is off.
4. Start the engine. For details, see “STARTING ENGINE (3-
189)“.
When the engine is stopped with the emergency stop switch, there is no need to bleed air from the fuel circuit.