MAINTENANCE PROCEDURE MAINTENANCE
4-82
1. Pull fuel shut-off lever (A) installed to the front of the main
pump inside the pump room, and close the fuel supply cir-
cuit from the fuel tank.
(S): Shut off
(O): Open
2. Set a container under the fuel pre-filter cartridge to catch
the fuel.
(Machine of poor fuel arrangement specification)