MAINTENANCE PROCEDURE MAINTENANCE
4-86
1. Pull fuel shut-off lever (A) installed to the front of the main
pump inside the pump room, and close the fuel supply cir-
cuit from the fuel tank.
(S): Shut off
(O): Open
2. Set the container to catch the fuel under the filter cartridge.
3. Using a filter wrench, turn filter cartridge (2) counterclock-
wise to remove it.
4. Clean the filter holder, coat the packing surface of the new
filter cartridge thinly with oil, then install the filter cartridge
to the filter holder.

Table of Contents