126
Switch on pump via PTO shaft.
Operate the pump at the rated speed.
Switch the diverting valve to the induc-
tion lock.
If necessary, regulate the performance
of the agitator regulation.
Open the valve for edge moistening and
fill approx. 10 l of the contents from the
main tank into the chemical inductor.
Fill the spray agent into the induction va-
lve.
Match the suction quantity, edge mois-
tening and intensity of the agitator nozz-
le to each other:
To prevent the induction gate overflo-
wing: Set the suction volume via the
suction valve.
Adjust the edge moistening so that the
spray agent being inducted runs off on
a sliding film to the suction opening.
Adjust the intensity of the agitator
nozzle so that the spraying agent is
dissolved.