127
After rinsing the spray agent:
Clean the empty spray agent canister.
See «
Cleaning empty canisters, page 130».
Rinse the chemical inductor with clean
water. See «Rinsing the chemical induc-
tor, page 135».
If canisters are not cleaned or the pipe sys-
tem is flushed:
Close (1) cover.
Swivel the induction valve upwards into
the transport position.
Fold lever (2) downwards.
Snap lever (2) into place.
Switch diverting valve to spraying mode.
Stir spraying agent, see "Working with
the device, page 143".
Adjust the performance of the agitator
control accordingly.