Display code Short designaon Default seng Seng range Address Category
P411.01 DI1 inversion Not inverted [0] Selecon list 0x2632:001 general
P411.02 DI2 inversion Not inverted [0] Selecon list 0x2632:002 general
P411.03 DI3 inversion Not inverted [0] Selecon list 0x2632:003 general
P411.04 DI4 inversion Not inverted [0] Selecon list 0x2632:004 general
P411.05 DI5 inversion Not inverted [0] Selecon list 0x2632:005 general
P412.00 Freq. threshold 0.0 Hz 0.0 ... 599.0 Hz 0x4005 general
P413.00 MOP startmode Last value [0] Selecon list 0x4003 general
P414.xx MOP start value
P414.01 Frequency 0.0 Hz 0.0 ... 599.0 Hz 0x4004:001 general
P414.02 PID value 0.00 PID unit -300.00 ... 300.00 PID unit 0x4004:002 general
P414.03 Torque 0.0 % 0.0 ... 1000.0 % 0x4004:003 general
P420.xx Dig.out.funcon
P420.01 Relay
funcon Rdy for operat. [51] Selecon list 0x2634:001 general
P420.02 DO1 funcon Release brake [115] Selecon list 0x2634:002 general
P421.xx DO inversion
P421.01 Relay inverted Not inverted [0] Selecon list 0x2635:001 general
P421.02 DO1 inversion Not inverted [0] Selecon list 0x2635:002 general
P430.xx Analog input 1
P430.01 AI1 input range 0 ... 10 VDC [0] Selecon list 0x2636:001 general
P430.02 AI1 freq @ min 0.0 Hz -1000.0 ... 1000.0 Hz 0x2636:002 general
P430.03 AI1 freq @ max Device for 50-Hz mains:
50.0 Hz Device for 60-Hz
mains: 60.0 Hz
-1000.0 ... 1000.0 Hz 0x2636:003 general
P430.04 AI1 PID @ min 0.00 PID unit -300.00 ... 300.00 PID unit 0x2636:004 general
P430.05 AI1 PID @ max 100.00 PID unit -300.00 ... 300.00 PID unit 0x2636:005 general
P430.06 AI1 lter me 10 ms 0 ... 10000 ms 0x2636:006 general
P430.07 AI1 dead band 0.0 % 0.0 ... 100.0 % 0x2636:007 general
P430.08 AI1 monit.level 0.0 % -100.0 ... 100.0 % 0x2636:008 general
P430.09 Monitoring cond. IN < threshold [0] Selecon list 0x2636:009 general
P430.10 AI1 error resp. Fault [3] Selecon list 0x2636:010 general
P430.11 Min. torque 0.0 % -400.0 ... 400.0 % 0x2636:011 general
P430.12 Max. torque 100.0 % -400.0 ... 400.0 % 0x2636:012 general
P431.xx Analog input 2
P431.01 AI2 input range 0 ... 10 VDC [0] Selecon list 0x2637:001 general
P431.02 AI2 freq @ min 0.0 Hz -1000.0 ... 1000.0 Hz 0x2637:002 general
P431.03 AI2 freq @ max Device for 50-Hz mains:
50.0 Hz De
vice for 60-Hz
mains: 60.0 Hz
-1000.0 ... 1000.0 Hz 0x2637:003 general
P431.04 AI2 PID @ min 0.00 PID unit -300.00 ... 300.00 PID unit 0x2637:004 general
P431.05 AI2 PID @ max 100.00 PID unit -300.00 ... 300.00 PID unit 0x2637:005 general
P431.06 AI2 lter me 10 ms 0 ... 10000 ms 0x2637:006 general
P431.07 AI2 dead band 0.0 % 0.0 ... 100.0 % 0x2637:007 general
P431.08 AI2 monit.level 0.0 % -100.0 ... 100.0 % 0x2637:008 general
P431.09 Monitoring cond. IN < threshold [0] Selecon list 0x2637:009 general
P431.10 AI2 error resp. Fault [3] Selecon list 0x2637:010 general
P431.11 Min. torque 0.0 % -400.0 ... 400.0 % 0x2637:011 general
P431.12 Max. torque 100.0 % -400.0 ... 400.0 % 0x2637:012 general
P440.xx Analog output 1
P440.01 AO1 outp. range 0 ... 10 VDC [1] Selecon list 0x2639:001 general
P440.02 AO1 funcon Outp. frequency [1] Selecon list 0x2639:002 general
P440.03 AO1 min. signal 0 -2147483648 ... 2147483647 0x2639:003 general
P440.04 AO1 max. signal 1000 -2147483648 ... 2147483647 0x2639:004 general
P450.xx Freq. presets
P450.01 Freq. preset 1 20.0 Hz 0.0 ... 599.0 Hz 0x2911:001 general
* Default seng dependent on the model.