Address Name Default seng Category Data type Factor A M
0x2DA5:016
(P111.16)
Diagnoscs of analog input 2: Status - (Read only) general U16 1 O -
0x2DAA:001
(P112.01)
Diagnoscs of analog output 1: Voltage x.xx V (Read only) general U16 100 O t
0x2DAA:002
(P112.02)
Diagnoscs of analog output 1: Current x.xx mA (Read only) general U16 100 O t
0x2DAC
(P119.00)
Keypad status - (Read only) general U16 1 O t
0x2DAD
(P120.00)
Internal hardware states - (Read only) general U16 1 O -
0x2DAE:001
(P140.01)
Sequencer
diagnoscs: Acve step - (Read only) Sequencer U8 1 O t
0x2DAE:002
(P140.02)
Sequencer diagnoscs: Step me elapsed x.x s (Read only) Sequencer I32 10 O t
0x2DAE:003
(P140.03)
Sequencer diagnoscs: Step me remaining x.x s (Read only) Sequencer I32 10 O t
0x2DAE:004
(P140.04)
Sequencer diagnoscs: Steps complete - (Read only) Sequencer I32 1 O t
0x2DAE:005
(P140.05)
Sequencer diagnoscs: Steps remaining - (Read only) Sequencer I32 1 O t
0x2DAE:006
(P140.06)
Sequencer diagnoscs: Acve sequence - (Read only) Sequencer U8 1 O t
0x2DAE:007
(P140.07)
Sequencer diagnoscs: Acve segment - (Read only) Sequencer U8 1 O t
0x2DAE:008
(P140.08)
Sequencer
diagnoscs: Relave sequence me
remaining
x % (Read only) Sequencer U8 1 O t
0x2DAE:009
(P140.09)
Sequencer diagnoscs: Absolute sequence me
remaining
x.x s (Read only) Sequencer I32 10 O t
0x2DAE:010 Sequencer diagnoscs: Frequency setpoint x.x Hz (Read only) Sequencer I16 10 - -
0x2DAE:011 Sequencer diagnoscs: PID setpoint x.xx PID unit (Read only) Sequencer I16 100 - -
0x2DAE:012 Sequencer diagnoscs: Torque setpoint x.x % (Read only) Sequencer I16 10 - -
0x2DD1:001 Motor currents: Actual D-current (id) x.xx A (Read only) MCTRL I32 100 O t
0x2DD1:002 Motor currents: Actual Q-current (iq) x.xx A (Read only) general I32 100 O t
0x2DD1:003 Motor currents: Setpoint D-current (id) x.xx A (Read only) general I32 100 O t
0x2DD1:004 Motor currents: Setpoint Q-current (iq) x.xx A (Read only) MCTRL I32 100 O t
0x2DD1:005 Motor currents: Motor current (Ie) x.xx A (Read only) MCTRL I32 100 O t
0x2DD3:003 Speed setpoint limited x rpm (Read only) MCTRL I32 1 O t
0x2DD5 Torque setpoint x.xx Nm (Read only) general I32 100 - t
0x2DDD
(P100.00)
Output frequency x.x Hz (Read only) general I16 10 O t
0x2DDF:001 Axis
informaon: Rated current x.xx A (Read only) general U16 100 O t
0x2DDF:002 Axis informaon: Maximum current x.xx A (Read only) general U16 100 O t
0x2DE0:009 Motor idencaon sengs 0 general U16 1 PC -
0x2DE0:010 V/f behavior 0 general U16 1 PC -
0x4002
(P702.00)
Speed display scaling 0.00 general U16 100 P -
0x4003
(P413.00)
MOP starng mode Last value [0] general U8 1 P -
0x4004:001
(P414.01)
MOP
starng values: Frequency 0.0 Hz general U16 10 P -
0x4004:002
(P414.02)
MOP starng values: PID value 0.00 PID unit general I16 100 P -
0x4004:003
(P414.03)
MOP starng values: Torque 0.0 % general U16 10 P -
0x4005
(P412.00)
Frequency threshold 0.0 Hz general U16 10 P -
0x4006:001
(P710.01)
Load loss detecon: Threshold 0.0 % general U16 10 P -
* Default seng dependent on the model.
Appendix
P
arameter aribute list
326