Colortran Encore Control Console
Software Version 3.05
92
? EXAMPLE: To turn all Bump buttons On or Off, or set them to Solo
or Toggle:
1. (SUB TYPE)
2. (ALL BUMPS) (BUMP ON) (Sets all Bump buttons On.)
- or -
(ALL BUMPS) (BUMP OFF) (Sets all Bump buttons Off.)
- or -
(ALL BUMPS) (SOLO BUMP) (Sets all Bump buttons to Solo
mode.)
- or -
(ALL BUMPS) (BUMP TOGGL) (Sets all Bump buttons to Toggle
mode.)
(It is not necessary to press the [ENTER] key.)
Timed Submasters
You can assign fade times to submasters in the Submaster display so that when
you press the Bump button, the submaster level fades up or down in the time
that you assign. Each submaster can be assigned a different time, and each
submaster can be assigned a separate up and down time. The current
submaster fade time is shown in the "Time" information field in the middle of
the Status Bar, in the Submaster display.
? EXAMPLE: To assign an up and down time of ten seconds to sub 5
in the Submaster display:
1. [SUB] [5] [ENTER] (Selects sub 5 as current
sub.)
2. [TIME] [10] [ENTER]
? EXAMPLE: To assign a split time with a 10 second up time and a
20 second down time to the current sub in the Submaster display:
[TIME] [10] [+] [20] [ENTER]
? NOTE: When a sub fader is at zero, the fade from Full to zero will
occur in the assigned sub fade time. When the sub fader is set at a level other
than zero, the fade time is proportional to the level. For example, if the fade
time is 10 seconds, and the fader level is at 30%, the fade from 30% to Full
takes 7 seconds.