Colortran Encore Control Console
Software Version 3.05
134
In cue 4:
?? Channel 1 remained a soft level because it did not need to change to a
hard level to keep the same
value of 10%.
?? Channel 2 remained a soft level because it did not need to change to a
hard level to keep the same
value of 20%.
?? Channel 3 became a hard level because it needed to in order to maintain
the same value of 30%.
?? Channel 4 remained a hard level at 40%.
Renumbering in Clean Up Mode: Renumbering cues in Clean Up
mode follows the same rules as in Cue Only mode. The results are not visible
while in Clean Up mode since no soft tracking levels are shown. The “hidden”
soft levels are converted to hard levels, as necessary, in the renumbered cue and
in the cue that follows the renumbered cue to maintain their assigned level
values.
?
HINT: To maintain the same “look” of a renumbered cue and the
next cue after the cue’s new location, do all Renumber commands in Cue Only
or Clean Up mode. Although you cannot see the tracking levels while in Clean
Up mode, both modes will preserve tracking levels where they can do so (where
level values do not change).