107
Learning Basic Features
Group
Code
Name
LCD Display
Parameter Setting
Setting Range
Unit
29
Jump frequency
upper limit1
Jump Hi 1 15.00
Jump frequency lower limit
1Maximum frequency
Hz
30
Jump frequency
lower limit 2
Jump Lo 2 20.00
0.00Jump frequency upper
limit 2
Hz
31
Jump frequency
upper limit 2
Jump Hi 2 25.00
Jump frequency lower limit
2Maximum frequency
Hz
32
Jump frequency
lower limit 3
Jump Lo 3 30.00
0.00Jump frequency upper
limit 3
Hz
33
Jump frequency
upper limit 3
Jump Hi 3 35.00
Jump frequency lower limit
3Maximum frequency
Hz
4.19 2
nd
Operation Mode Setting
Apply two types of operation modes and switch between them as required. For both the first and
second command source, set the frequency after shifting operation commands to the multi-
function input terminal. Mode swiching can be used to stop remote control during an operation
using the communication option and to switch operation mode to operate via the local panel, or
to operate the inverter from another remote control location.
Select one of the multi-function terminals from codes In. 6571 and set the parameter value to 15
(2nd Source).
Group
Code
Name
LCD Display
Parameter Setting
Setting Range
Unit
Opera
tion
drv
Command source
Cmd Source*
1
Fx/Rx-1
0–5
-
Frq
Frequency reference
source
Freq Ref Src 2 V1 012 -