11 Technical Specification
11.1 Input and Output Specification
Single Phase 200V (0.4-2.2 kW)
Model
□□□□
S100
–
1
□□□□□
motor
Heavy load
HP 0.5 1.0 2.0 3.0
kW 0.4 0.75 1.5 2.2
Normal load
HP 1.0 2.0 3.0 5.0
kW 0.75 1.5 2.2 3.7
(kVA)
(A)
0-400 Hz (IM Sensorless: 0-120 Hz)
Single phase 200-240 V AC (-15% to +10%)
50-60 Hz (±5%)
(A)
Weight (lb /kg)
(Built-in EMC filter)
• The standard motor capacity is based on a standard 4-pole motor.
• The standard used for 200 V inverters is based on a 220 V supply voltage, and for 400V
inverters is based on a 440 V supply voltage.
• The rated output current is limited based on the carrier frequency set at Cn.04.
• The output voltage becomes 20~40% lower during no-load operations to protect the
inverter from the impact of the motor closing and opening (0.4~4.0kW models only).